ICC-ES AC373
Full Name
ICC-ES AC373 – Acceptance Criteria for Precast Reinforced Cementitious Slurry Structural MembersScope
ICC-ES AC373 outlines the acceptance criteria for precast reinforced cementitious slurry structural members used in building construction. These members are typically made of a cementitious mixture reinforced with steel wire mesh or fibers and cast into molds to create various structural components like beams, columns, walls, and panels. The scope of AC373 includes:- Material properties: it specifies the requirements for the cementitious slurry mix, including its composition, strength, and durability, as well as the requirements for the steel reinforcement used in the members.
- Design: it outlines the design criteria for precast reinforced cementitious slurry structural members, including their dimensions, reinforcement details, and connection requirements to ensure structural integrity and stability under various load conditions.
- Testing: it details the specific tests required to evaluate the structural performance of these members, including flexural tests, shear tests, and connection tests, as well as tests for fire resistance and durability.
- Evaluation: it provides a framework for evaluating precast reinforced cementitious slurry structural members to ensure they comply with the acceptance criteria, including a review of their design, material properties, and test results.