Test Plan for ASTM C207 Hydrated Lime for Masonry Purposes
Testing services for your products and materials
Test Plan for ASTM C207 Hydrated Lime for Masonry Purposes
Test Plan for ASTM C207 Hydrated Lime for Masonry Purposes
Required Tests
Property | Material | ASTM / Method | Details |
---|---|---|---|
Chemical Composition | Lime Powder | ASTM C25 | Calcium and Magnesium Oxides (nonvolatile basis), Carbon Dioxide (as-received basis), Unhydrated Oxides (as-received basis, only required for type S / SA) |
Residue, Popping, and Pitting | Lime Powder | ASTM C110 | Residue Retained on a #30 Sieve. If residue is > 0.5%, sample must be tested for popping / pitting. |
Popping / Pitting | Lime Powder | ASTM C110 | Per ASTM C110 Section 10. Only required if residue retained on #30 sieve is >0.5% |
Plasticity | Lime Putty | ASTM C110 | Only Required for Type S and Type SA Hydrate Types. Shall be not less than 200 Elmey units when tested within 30 min |
Water Retention | Lime Mortar | ASTM C110 | Type N / NA > 75% Water Retention Type S / SA > 85% Water Retention |
Air Entrainment | Lime Mortar | ASTM C110 | Per ASTM C110 Section 8. Type N / S shall have < 7% Air Content Type NA / SA shall have between 7% and 12% Air Content |
Please contact us for technical details and pricing.
You can view our complete listing of accredited standards and more information on masonry testing.