Test Plan for ASTM C207 Hydrated Lime for Masonry Purposes

Required Tests

PropertyMaterialASTM / MethodDetails
Chemical CompositionLime PowderASTM C25Calcium and Magnesium Oxides (nonvolatile basis), Carbon Dioxide (as-received basis), Unhydrated Oxides (as-received basis, only required for type S / SA)
Residue, Popping, and PittingLime PowderASTM C110Residue Retained on a #30 Sieve.
If residue is > 0.5%, sample must be tested for popping / pitting.
Popping / PittingLime PowderASTM C110Per ASTM C110 Section 10.
Only required if residue retained on #30 sieve is >0.5%
PlasticityLime PuttyASTM C110Only Required for Type S and Type SA Hydrate Types.
Shall be not less than 200 Elmey units when tested within 30 min
Water RetentionLime MortarASTM C110Type N / NA > 75% Water Retention
Type S / SA > 85% Water Retention
Air EntrainmentLime MortarASTM C110Per ASTM C110 Section 8.
Type N / S shall have < 7% Air Content
Type NA / SA shall have between 7% and 12% Air Content

 

Please contact us for technical details and pricing.