Masonry

MASONRY, CMU, GROUT and MORTAR LAB TESTING
 
Do your CMUs meet the specs? Have Applied Testing & Geosciences, LLC certified laboratory test:
 
Flexural strength
Loss on Ignition
Calcium Chloride
Modulus of Rupture
Density
Freeze Thaw
Moisture Vapor Emission Rates
Petrographic
Alkali Potential
Chemical Analysis
Compressive strength
 
For more tests see below.
 
CERTIFICATIONS
American Concrete Institute - Lab Testing Technician - Grade II
NICET - Construction Materials Testing - Concrete Level I, II
Professional Geologists
Professional Engineers
   
ASTM MASONRY, CMU, GROUT and MORTAR LAB PROCEDURES
Alkali Potential Reactivity of Aggregates (Mortar-Bar Method) (C1260)
Alkali Potential Reactivity of Cement-Aggregate Combinations (Mortar-Bar Method) (C227)
Alkali-Silica Potential Reactivity of Aggregates (Chemical Method) (C289)
Bond Strength of Epoxy-Resin Systems Used With Concrete By Slant Shear (C882)
Brick and Structural Clay Tile (C67)
Chemical Analysis of Limestone, Quicklime, and Hydrated Lime (C25)
Compressive Strength of 2"x2"x2" Cube (C109)
Compressive Strength of Grouts for Preplaced-Aggregate Concrete (C942)
Compressive Strength of 3"x3"x3" Cube (C109)
Compressive Strength of masonry cylinders (C39)
Compressive Strength of 2" Diam masonry core (C42)
Compressive Strength of 3" Diam masonry core (C42)
Compressive Strength of 4" Diam masonry core (C42)
Compressive Strength, Absorption, Unit Weight, Moisture, Flexural Strength of Concrete Masonry Units. (C140)
Compressive Strength - Masonry Prism Test (C1314)
Compressive Strength - Set-up Charge Prism (C1314)
Consistency of Hydraulic Cement (C187)
Density of Hydraulic Cement (C188)
Early Stiffening of Hydraulic Cement (Mortar Method) (C359)
Evaluation of Mortars for Plain and Reinforced Unit Masonry (C780)
Expansion and Bleeding of Freshly Mixed Grouts for Preplaced-Aggregate Concrete (C940)
Flexural Bond Strength of Masonry (E518)
Flexural Strength of Hydraulic-Cement Mortars (C348)
Flow of Grout for Preplaced-Aggregate Concrete (Flow Cone Method) (C939)
Flow of Hydraulic Cement Mortar (C1437)
Length Change of Hardened Hydraulic-Cement Mortar and Concrete (C157/C 157M)
Length Change at Early Ages of Cylindrical Specimens of Cementitious Mixtures (C827)
Length Change of Cylindrical Specimens of Hydraulic-Cement Grout (C1090)
Length Change of Hydraulic-Cement Mortars Exposed to a Sulfate Solution (C1012)
Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic Consistency (C305)
Physical Testing of Quicklime, Hydrated Lime, and Limestone (C110)
Saw cutting of masonry specimens
Shear in Masonry Assemblages (E519)
Spec for Aggregates for Masonry Grout (C404)
Spec for Grout for Masonry (C476)
Spec for Hydrated Lime for Masonry Purposes (C207)
Spec for Mortar for Unit Masonry (C270)
Splitting Tensile Strength of Masonry Units (C1006)
Time of Setting of Hydraulic Cement by Vicat Needle (C191 - 01)
Time of Setting of Hydraulic-Cement by Gillmore Needles (C266 - 99)
Time of Setting of Grouts for Preplaced-Aggregate Concrete (C953 - 87)
Water Penetration and Leakage Through Masonry (E514)

  

MASONRY SERVICES
Click here to schedule Masonry Testing
Click here for Masonry Inspection 
Contact Info